Thomas Kunz
Systems and Computer Engineering
20
CDPD: Intra-Area Cell Transfer
–intra-area cell transfer: controlled by same MD-IS
–M-ES initiates transfer if channel becomes bad (extended loss of channel synchronization and/or unacceptable error rate) –to assist M-ES in locating CDPD channel, MDBS periodically broadcasts RF channel number in use or as candidates for use in adjacent cell –after M-ES synchronized with new RF channel, sends link-layer receive ready to serving MD-IS –MD-IS acknowledges frame and updates its information for M-ES (physical media association)